Resources: click to jump down the page:

|
Click on the thumbnails below for larger images. |
|
|
|
|
|
|
Proptec™ Series Hydraulic-powered Atomizers
Choose a Proptec™ hydraulic-powered atomizer when any of the following design conditions apply to you:
- Mobile applications
- Small size and weight of the atomizer is desirable
- Environment too hot for an electric motor (e.g. stacks & flues)
- Spray environment too corrosive for an electric motor
- Cannot risk electricity or electric fields in spray application
- Continuous high speeds (5000 RPM or higher) are desired, ie: for high volume fogging or misting applications over 2 gallons per minute (higher power demand).
- Very high spray rates (over 4 gallons (16 l ) per minute.
- High volume air assist and high volume spray are required in unison
- Hydraulic power is available, or there is an engine-driven powersource that could provide hydraulic power
If none of these conditions apply to you, you may want to consider our PENGUIN™series electric powered atomizers.
Proptec atomizers are available in several basic configurations, depending on your needs. If you haven't already visited one of these pages, click the links below to learn more about each type, and how it may apply to your application.
Why a Proptec atomizer?
- Very fine to ultra coarse droplet spectrum with nearly any fluid, adjusted by speed and component choice
- Atomizer is virtually clog-proof, unaffected by wear
- Unique radial spray pattern- standard atomizer:
- Great for cylindrical flows such as seed treaters, prilling, and other bulk treatment processes
- Fast dispersion of fluids over large areas
- Flow rates that are impossible with high pressure nozzles
- Conical spray pattern with air-assist option:
- Resists wind to spray long distances
- Directs spray at process
- Incredible mixing of air and spray for excellent coverage or dispersion
- Higher volume of air than air-atomizing nozzles and competing rotary atomizers for longer travel
- Efficient, uses ultra high efficiency hydraulic motor, low power draw, runs cool
- Incredibly long service life for unattended operation and low operating cost
- Flexible configuration: mix and match components to fit your exact needs. Easily reconfigure if your needs change
Stock models & common configurations:
Below are some of the most common Proptec Atomizer configurations. For air-assisted and guarded atomizers, please visit this page.
| Picture |
Callout |
Description |
Price |
 |
PT048 |
Proptec PT048 coarse droplet atomizer
- Max oil consumption: 2.5 GPM. 500-1100 PSI typical operating pressure. Max RPM: 6000.
- Max fluid flow: 0-2.5 GPM as specified, up to 4 GPM possible.
- Weight: approximately 3 pounds (1.5 kg)
- Noise: 65 decibels
- Max particulate in sprayed fluid: .100" (2 mm)
- Mount directly to isolation mounting. For directional mounting capability, purchase bail and boom mount brackets separately
|
|
 |
PT098 |
Proptec PT098 coarse droplet atomizer
- Max oil consumption: 5 GPM. 250-600 PSI typical operating pressure. Max RPM: 6000.
- Max fluid flow: 0-2.5 GPM as specified, up to 4 GPM possible.
- Weight: approximately 3 pounds (1.5 kg)
- Noise: 65 decibels
- Max particulate in sprayed fluid: .100" (2 mm)
- Mount directly to isolation mounting. For directional mounting capability, purchase bail and boom mount brackets separately
|
|
 |
PT098-HF |
Proptec PT098 coarse droplet atomizer, high flow
- Max oil consumption: 5 GPM. 250-600 PSI typical operating pressure. Max RPM: 6000.
- Max fluid flow: 0-6 GPM as specified, up to 12 GPM possible.
- Weight: approximately 4 pounds (1.5 kg)
- Noise: 65 decibels
- Max particulate in sprayed fluid: .150" (2 mm)
- Mount directly to isolation mounting. For directional mounting capability, purchase bail and boom mount brackets separately
|
|
 |
PT049-20-T1-0230
(lo-HP hydraulic)
or
PT099-20-T1- 0230
(hi-HP hydraulic) |
Proptec PT049/PT099 dual stage atomizer, 6" fine mesh basket
- Max oil consumption PT049: 2.5 GPM. 500-1100 PSI typical operating pressure. Max RPM: 6000.
- Max oil consumption PT099: 5 GPM. 300-800 PSI typical operating pressure. Max RPM: 6000.
- Max fluid flow: 0-2 GPM, optimum range 0-.5 GPM
- Weight: approximately 3 pounds (1.5 kg)
- Noise: 65 decibels
- Droplet spectrum: very fine/near fog. Narrow spectrum.
- Max particulate in sprayed fluid: .016" (.4 mm)
- Mount directly to isolation mounting. For directional mounting capability, purchase bail and boom mount brackets separately
|
|
 |
PT049-20-T1-0200
(lo-HP hydraulic)
or
PT099-20-T1- 0200
(hi-HP hydraulic) |
Proptec PT049/PT099 dual stage atomizer, 6" coarse mesh basket
- Max oil consumption PT049: 2.5 GPM. 500-1100 PSI typical operating pressure. Max RPM: 6000.
- Max oil consumption PT099: 5 GPM. 300-800 PSI typical operating pressure. Max RPM: 6000.
- Max fluid flow: 0-3.5 GPM as specified, up to 6 GPM possible. Higher than fine mesh basket.
- Weight: approximately 3 pounds (1.5 kg)
- Noise: 65 decibels
- Droplet spectrum: Very fine to fine spectrum.
- Max particulate in sprayed fluid: .060" (2 mm)
- Mount directly to isolation mounting. For directional mounting capability, purchase bail and boom mount brackets separately
|
|
 |
PT049-20-T1-2230
(lo-hp hydraulic)
or
PT099-20-T1- 2230
(hi-hp hydraulic) |
Proptec PT049/PT099 dual stage atomizer, 12 " fine mesh basket
- Max oil consumption PT049: 2.5 GPM. 1500-2200 PSI typical operating pressure. Max RPM: 6000.
- Max oil consumption PT099: 5 GPM. 800-1700 PSI typical operating pressure. Max RPM: 6000.
- Max fluid flow: 0-3.5 GPM, optimum range 0-2 GPM. Other configurations up to 8 GPM
- Weight: approximately 3 pounds (1.5 kg)
- Noise: 65 decibels
- Droplet spectrum: very fine/near fog. Narrow spectrum.
- Max particulate in sprayed fluid: .016" (.4 mm)
- Mount directly to isolation mounting. For directional mounting capability, purchase bail and boom mount brackets separately
|
|

fine mesh basket shown |
PT049-60-T1-2200
(lo-hp hydraulic)
or
PT099-60-T1- 2200
(hi-hp hydraulic) |
Proptec PT049/PT099 dual stage atomizer, 12" coarse mesh basket
- Max oil consumption PT049: 2.5 GPM. 1500-2200 PSI typical operating pressure. Max RPM: 6000.
- Max oil consumption PT099: 5 GPM. 800-1700 PSI typical operating pressure. Max RPM: 6000.
- Max fluid flow: 0-3.5 GPM as specified, up to 12 GPM possible. Higher than fine mesh basket.
- Weight: approximately 3 pounds (1.5 kg)
- Noise: 65 decibels
- Droplet spectrum: very fine
- Max particulate in sprayed fluid: .060" (2 mm)
- Mount directly to isolation mounting. For directional mounting capability, purchase bail and boom mount brackets separately
|
|
 |
PT099-35A-T1-2200 |
Proptec PT099 dual stage atomizer, 12" coarse mesh basket, air-assisted
- Not offered as PT049 series.
- Max oil consumption: 4 GPM. 2500 PSI typical operating pressure. Max RPM: 5500.
- Max fluid flow: 0-3.5 GPM as specified, up to 6 GPM possible.
- Weight: approximately 4 pounds (1.5 kg)
- Noise: 95 decibels
- Droplet spectrum: very fine.
- Max particulate in sprayed fluid: .060" (2 mm)
- Unguarded fan- must be installed in an inaccessible location
- Mount directly to isolation mounting. For directional mounting capability, purchase bail and boom mount brackets separately
|
|
|
Product Dimensions:
- Approximate base body dimensions:
- 5.0" x 7.0" x 9.5" (127mm x 178mm x 241mm)
- This will vary by configuration.
Click on the following links for dimensions of the most common Proptec™atomizer configurations. Available in PDF format or as 3D drawings.
Configure your atomizer:
Want to configure your own, see all the options, or compare options pricing? Following is the complete callout. Click links to learn about the individual options, and download the forms to design your complete atomizer. For complete systems, visit the Kits section.
Design Options:
|